TEMP-STAR*
-
Where can I get a short overview of the actual functions?
-
With a push on the „HELP“ button, a specific description of the actual display view and the possible functions that come with it is being displayed.
Category: Tempstar-Professional, TEMPSTAR* -
How many zones can be managed by the visualisation software?
-
Up to 180 zones are possible.
Category: Tempstar-Professional, TEMPSTAR* -
Is there a possibility to change the user language?
-
Yes, currently the languages German, English, and Spanish are available.
Category: Tempstar-Professional, TEMPSTAR* -
What is the meaning of „E04“ on the user display?
-
This is an error caused by the storing of last data. if you change any settings, please leave the device a few minutes with the power supply on to allow the data being saved in the memory.
Category: Tempstar-MULTI, TEMPSTAR* -
What is the meaning of „E32“ on the user display?
-
There is a problem with the mains supply. at least one of the necessary mains phases is not present.
Category: Tempstar-Professional, TEMPSTAR* -
A short time after startup, NO COM is being displayed.
-
The communication to the controller cards could not be established. please check if all the cards have close contact with their connectors.
Category: Tempstar-MULTI, TEMPSTAR* -
Which signals can be connected to the external alarm in- and outputs?
-
A contact at the input 1 forces the controller into standby mode, a contact at the input 2 forces the controller into boost mode. the contacts of the output 1 are closed in case of over temperature, the contacts of the output 2 are closed in case of under temperature.
Category: Tempstar-MULTI, TEMPSTAR* -
A short time after startup, the controller gets into alarm mode. the LEDs of temperature and current are on.
-
There is no connection to the heater.
Category: Tempstar-Dialog/Single/Mini, TEMPSTAR* -
Which signals can be connected to the external alarm input and output?
-
A contact at the input forces the controller into standby mode. in case of alarm the contacts of the output are closed.
Category: Tempstar-Dialog/Single/Mini, TEMPSTAR* -
Which type of thermocouple can be connected to the controller?
-
Thermocouples consisting of FeCuNi, types J and L can be used.
Category: TEMPSTAR* general, TEMPSTAR* -
What is the maximum possible load current handled by the output stage?
-
Each zone can handle up to 16 amps, but please be sure not to exceed the wattage of the device.
Category: TEMPSTAR* general, TEMPSTAR* -
Are there special mains supply configurations available?
-
Yes, please request the sales department for your specific needs.
Category: TEMPSTAR* general, TEMPSTAR* -
What is the reason for unstable temperatures?
-
During the softstart ramp, the characteristic of the control loop is being detected. therefore it is important not to interrupt or shorten this phase. depending on the process, a lot of friction can be appear, which cannot always be cancelled by the controller. another reason for bad temperature control is insufficient thermal coupling or defects of the thermocouple.
Category: TEMPSTAR* general, TEMPSTAR* -
The temperature of the system doesn’t rise higher than a particular value.
-
At least one zone has a problem with rising the temperature. please switch off all unused zones and check the wiring.
Category: TEMPSTAR* general, TEMPSTAR*